PART 1 GENERAL
1.01 DESCRIPTION
A. Division 28 Contractor shall furnish and install a complete Security and Access Control
System as shown on the Drawings and as specified herein. Provide all accessories and
equipment as necessary for a complete system.
B. System shall be complete with control panels, door contacts, motion detectors, keypads,
power supplies, batteries, phone line dialer, audible devices, supervised wiring, and all
other items required for a complete fully functioning system.
C. Electric strikes/latches and power supplies are provided by the door hardware supplier.
This Contractor is required to coordinate with door hardware supplier and Division 26
Contractor, and is responsible for final connections to access control system including
integration with automatic handicap door operators.
D. The security system shall provide both monitor and control interface to the CCTV System
(Section 28 23 00, "Video Surveillance System"). The input interface shall monitor
selected video motion alarm contact closures from the CCTV System, causing an alarm
when un-authorized motion is detected by the CCTV System. The output interface shall
provide contact closures to the CCTV System to start video recording at full speed for
selected cameras when an alarm occurs.
1.02 QUALITY ASSURANCE
A. All equipment shall be UL listed and labeled, and in accordance with applicable NEMA
and ANSI Standards.
1.03 SUBMITTALS
A. For Review:
1. Product data sheets of all components
2. Wiring Diagrams
3. Full Size Lay-out Drawings
B. To be included in Record and Information Manuals:
1. One copy of each approved submittal
2. Test results
3. Certificate of System Completion
4. Certificate of Material Receipt
1.04 MANUFACTURERS
A. Intrusion Detection Alarm System
1. DMP
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION 28 15 00 INTRUSION DETECTION 13-HC1-033 28 15 00-1 PART 1 GENERAL 1.01 DESCR

Page 2

SECTION 28 15 00 INTRUSION DETECTION 28 15 00-2 13-HC1-033 B. UPS 1. APC 2. Best 3. Tripp-Lite C. Existing Security Contractor: Schmi

Page 3

SECTION 28 15 00 INTRUSION DETECTION 13-HC1-033 28 15 00-3 G. The system shall be capable of offering at least five zone expansion buses, e

Page 4

SECTION 28 15 00 INTRUSION DETECTION 28 15 00-4 13-HC1-033 G. Proximity card readers shall read cards up to 4 inches away, fit in a standar

Page 5

SECTION 28 15 00 INTRUSION DETECTION 13-HC1-033 28 15 00-5 J. Each access control point shall have two dedicated relay outputs. Both relay

Page 6

SECTION 28 15 00 INTRUSION DETECTION 28 15 00-6 13-HC1-033 C. Refer to Section 26 08 40, "Electrical Tests, Adjustments, Inspection.&q

Commentaires sur ces manuels

Pas de commentaire