XR500 Series Canadian Programming Guide Digital Monitoring Products
43
PC log rePorTS
17.10
DOOR ACS NO YES
Door Access Reports
Sends door access activity: door number, user number and name, and time and date.
17.11
SUPV MSG NO YES
Supervisory Reports
Sends system monitor reports, such as AC and battery, and system event reports.
Supervisory Reports also sends the following reports:
• Abort • ExitError • Ambush
• SystemRecentlyArmed • AlarmBellSilenced • UnauthorizedEntry
• *LatetoClose
*OnlysentasaSupervisoryReportifArea Schedules is not enabled, Closing
Checkisenabled,andanopening/closingschedulehasbeenprogrammed.
Note: TosendthesereportstothePCLog,youmustenableSUPVMSG.
17.12 PC Log Real-Time Status
SelectYEStosendReal-TimeStatusreportsforzones,doors,andoutputs.The
specicreportsmustalsobeselectedbyindividualzoneoroutput.TheReal-Time
StatusmessagesaresenttoaPCrunningagraphicdisplaysoftware.DefaultisNO.
The messages that can be sent are:
DoorOpenwithzonenumber•
Door Closed with zone number•
DoorOpenwithdoornumber•
Door Closed with door number•
OutputOn•
OutputOff•
OutputPulse•
OutputTemporal•
PC LOG REAL-TIME
STATUS
NO YES